ZETA EMC
Proficiency testing (PT) · EMC & radio

Interlaboratory comparison for electromagnetic compatibility and radio

ZETA is an independent laboratory guaranteeing impartiality and confidentiality for every proficiency testing campaign, from enrolment to final performance statistics.

ISO/IEC principles applied
17043
ISO/IEC principles applied
reference lab comparison
17025
reference lab comparison
ZETA-ONE-16 proficiency testing artefact with its conducted/radiated mode switch

Instrumentation calibrated for every campaign

Built for laboratories preparing for ISO/IEC 17025 accreditation, or maintaining it through recognized proficiency testing schemes.

Why laboratories choose ZETA

Rapid, expert-designed programs that turn interlaboratory comparison into a fast, reliable, and cost-effective exercise.

Fast, efficient programs
Test programs with measurements that take less than two hours, designed by experienced testing experts, built to run without delay from enrolment to report.
Short campaigns, quick results
Multiple identical, qualified samples circulate in parallel, so every round delivers results fast without waiting on a single chain of labs.
Optimized pricing
Lean, focused campaigns and transparent cost calculation keep proficiency testing affordable for every laboratory, large or small.Learn more about pricing
On-demand comparison
Run a campaign whenever you need it, benchmarked against an ISO/IEC 17025 accredited reference laboratory rather than a fixed yearly calendar.

Why proficiency testing matters

ISO/IEC 17025 accredited laboratories are expected to regularly demonstrate the validity of their results. Participation in proficiency testing or interlaboratory comparison as defined in ISO/IEC 17043 is the mechanism accreditation bodies rely on most to verify that competence over time.

In a typical round, identical samples are circulated to every participating laboratory. Each lab measures the sample under its own normal conditions, and the results are compared statistically against an assigned or consensus value, usually expressed as a z-score or an En number.

ZETA designs every campaign around the principles of ISO/IEC 17043: verified sample homogeneity and stability, a sound statistical design, and confidential reporting, so your lab can act on its performance without exposing it to competitors.

Reading your report

z-score
How many standard deviations your result sits from the assigned value. |z| ≤ 2 is generally considered satisfactory.
En number
Normalizes the difference by combined measurement uncertainty. |En| ≤ 1 indicates a result consistent with the reference value.
Semi-anechoic EMC test chamber with a log-periodic antenna on its mast

How a campaign runs

Five steps from enrolment to a report you can act on.

  1. 1

    Enrol & define scope

    Tell us which standards, frequency ranges, and test methods matter to your lab. We confirm scope and timing before anything ships.

  2. 2

    Receive your sample

    An identical, pre-qualified sample is shipped to every participating laboratory, checked beforehand for homogeneity and stability.

  3. 3

    Test under normal conditions

    Run the measurement exactly as you would for a client, using your own procedures, equipment, and personnel — no special treatment.

  4. 4

    Submit your results

    Report your results through a simple, structured template before the round closes. Late data can still be accommodated on request.

  5. 5

    Review your performance statistics

    Receive a confidential report with z-scores or En numbers benchmarked against the assigned value and our ISO/IEC 17025 reference laboratory.

Standards covered, by domain

Programs can be organized around any of the following domains, or adapted to a scope specific to your laboratory.

ZETA-ONE-16 artefact in its transport case, with cables and the CISPR 16-2-1 test instructions

Emissions & immunity methods

The general measurement methods every campaign is built on.

  • CISPR 16-2-1 & CISPR 16-2-3

    Conducted and radiated disturbance measurement methods, the reference for most emissions testing.

Automotive

Component and vehicle-level EMC for the automotive supply chain.

  • CISPR 25

    Radio disturbance characteristics for the protection of on-board receivers in vehicles, boats and devices.

  • ISO 11452-x

    Component immunity to narrowband radiated electromagnetic energy for road vehicles.

Industrial & generic

Immunity requirements shared across industrial equipment.

  • EN IEC 61000-4-x

    The industrial EMC immunity test series covering RF fields, bursts, surges and dips.

Aerospace & defense

Environmental and electromagnetic effects trials for regulated platforms.

  • DO-160

    Environmental conditions and test procedures for airborne equipment, sections 16 to 25.

  • AECTP 500

    NATO electromagnetic environmental effects trials for military platforms and equipment.

  • MIL-STD-461

    US military EMI/EMC requirements for the control of electromagnetic interference in equipment and subsystems.

Ready to schedule a campaign?

Tell us about your lab and testing scope. We will put together a program that fits, usually within five business days.